ARTECHE RELAYS PDF

Arteche manufactures trip and lockout relays with a wide range of options to met each application requirements. Reliability an performance by default for. Installed in more than countries, Arteche relays are the best choice for applications such as trip high and medium voltage breakers, safety critical logics in. Instantaneous relays contacts change instantaneously from non-working position to working position when its coil is energized, coming back contacts to the.

Author: Vozshura Melar
Country: Equatorial Guinea
Language: English (Spanish)
Genre: Science
Published (Last): 8 September 2009
Pages: 261
PDF File Size: 1.18 Mb
ePub File Size: 9.70 Mb
ISBN: 564-1-46233-299-3
Downloads: 16096
Price: Free* [*Free Regsitration Required]
Uploader: Kagakasa

Trip relays Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized.

Depending on which coil is energized, the contacts will change from one position to the other. Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply.

Connecting the relay across the trip circuit relayss, the equipment is normally energized. Through a small supervision current the whole circuit is supervised, in both positions of the circuit breaker opened or closed. Trip relays with 2 stable positions for the output contacts.

Most 10 Related  BREVE HISTORIA DE LAS DOCTRINAS ECONOMICAS GOMEZ GRANILLO PDF

The contacts return to the rest position when the coil is no longer energized. Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized. Trip circuit erlays relays For single phase or three phase circuit breakers.

KRIMP & WEDGE, INC. – ARTECHE, Spain

For single phase or three phase circuit breakers. This range includes relay with 4 and 8 contacts, with operating times below 8 ms or 10 ms, depending on the model, and possibility of manual reset. In order to avoid faulty alarms due to instantaneous supply voltage dips, the drop off time of the relay is delayed over ms so those non-permanent failures of trip supply would not be considered.

Trip and lockout relays Trip relays with 2 stable positions for the output contacts. It uses reference signal from GPS Global Positioning System and features wide variety of outputs and time coding standards.

Most 10 Related  DER EINDIMENSIONALE MENSCH MARCUSE PDF

TMS/Arteche Latching Auxiliary Relay

The correct state of the circuit is showed with a green LED on the front plate artechr the relay. This range includes relays with 2, 4 and 8 contacts, with operating times from 3 ms to 8 ms, depending on the model.

Auxiliary supply circuit supervision relays Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply. Faults will occur when the trip voltage is lost, so the relay drops off in those cases, providing the related signs and alarms.

The output contacts change its position if the relay detects a failure in the continuity of the circuit.